How to check commutator motors
SSD-P APdV, EB, HD 01/05 9.1 599 34 71-47
How to check commutator motors
1) Check connecting blocks (wiring) and if there are any stuck out / folded terminals
2) Check if there are any water or detergent traces / remaining / deposits and where
they come from
3) Control any windings / mass particulars or with a very low ground insulation by using
a tester with minimum capacity of 40 Mohm between every single terminal and the
housing (read ).
4) Check every single winding according to the following table
Motor junction
box terminals
Check of:
SOLE Motor
[ Ohms ]
F.H.P. Motor
[ Ohms ]
CE.SE.T.Motor
[ Ohms ]
171 ÷ 196
A
3 - 4
Tachymetric
generator winding
469 ÷ 540
126 ÷ 147 64 ÷ 73
B
5 - 10
Stator winding
(all field)
1.0 ÷ 2.2 1.0 ÷ 3.0 1.0 ÷ 2.0
C
6 - 7
Thermo-protection
(cut - off)
00 0
D
8 - 9
Rotor winding 1.5 ÷ 3.0 1.5 ÷ 3.0 1.5 ÷ 3.0
E
1 - 10
Stator winding
(half field,
terminal 1)
0.5 ÷ 1.0 0.5 ÷ 1.5 0.5 ÷ 1.0
Note: while controlling rotor winding, you have to measure all the section by rotating the shaft
very slowly and check if there are any short-circuits between the visible bars.
Check also the wear state of brushes.