Part 1 - INSTALLATION INSTRUCTIONS
2.4 - Choice of operating mode
a) Evacuation mode
To check that the hood is set up for evacuation, open
the grille panel and make sure that the conversion lever
or the change-over knob on the centrifugal unit is in
the DUCTING position (B). The charcoal filter is not
required. For ducting to the outside, the hood is
supplied with a rear and top outlet. A flange spigot of
100 mm diameter (120 mm in certain models) is usually
fitted on the top outlet and a blanking plug on the rear
outlet. If you choose to duct the hood from the rear of
the casing, you should invert the position of the flange
and of the blanking plug. Pay attention to the safety
regulation 1.1.
b) Internal recirculation mode
To check that the hood is set up for recycling, open
the grille panel and make sure that the conversion lever
or the change-over knob on the centrifugal unit is in
the RECYCLING position (A). The charcoal filter is to
be fitted. To fit the charcoal filter, support the filter with
one hand and turn the thumb screw through the centre
of the charcoal filter. If the filter is of the interlocking
type, turn the filter clockwise. The hood can remain
connected to the outside.
2.5 - Electrical connection and
working test
1 - The safety measures 1.2, 1.3, 1.4 and 1.5
of paragraph 1 are to be strictly observed.
2 - Once the electrical connection has been
completed, check that the worktop
illumination, motor and speeds work
properly.